How to Program a Renishaw Probe to Automatically Adjust Tool Offsets and Recut Parts

If you have further questions on Renishaw probe programming, please contact us at (--CUT FEATURE--) N1 T14 M6 (--MEASUREMENT--) T25 M6 (PROBE CALL) G54 (WORK OFFSET ACTIVE) G43 H25 (TOOL OFFSET ACTIVE) G65 P9832 (PROBE ON) G65 P9810 X0 Y0 F200. (MOVE TO X0 Y0) G65 P9810 Z-0.5 F200. (MOVE TO Z-0.5) G65 P9814 (I.D. MEASURE FOR BORE) G65 P9810 Z1.0 F200. (MOVE TO Z1.0) G65 P9833 (PROBE OFF) G0 G53 Z0 (RAPID TO Z HOME) #100=#138 (SAVE MEASURED DIAMETER SIZE TO #100) (--ANALYSIS--) IF [#100 GT ] GOTO10 (CHECK FOR OVERSIZE) IF [#100 LT ] GOTO20 (CHECK FOR UNDERSIZE) GOTO30 N10 (LEAST MATERIAL CONDITION) #3000=10 (REJECT PART) N20 (MOST MATERIAL CONDITION) #[2400+14]=#[2400+14]-[ -#100]/2. GOTO1 N30 (OK!) T15 M6 (NEXT OPERATION)